3040-00-099-2158 SHAFT,SHOULDERED Index 4710-00-099-2161 TUBE ASSEMBLY,COORDINATION UNIT

National Stock Number:
6145-00-099-2159

Federal Supply Class:
6145

National Item Identification Number:
000992159

Description:
WIRE,ELECTRICAL

Detail:
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. refers to buld quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE.


Manufacturer Information:
22759/2-20-292607CARLISLE INTERCONNECT TECHNOLOGIES INC
75902-20-212515NEXANS AEROSPACE USA LLC
M22759/2-20-20U583SAE INTERNATIONAL
M22759/2-20-281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-W-22759/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
SAE-AS22759/20U583SAE INTERNATIONAL


Techincal Specification:
COLORRED 1ST POSITION COVER SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.094 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
ROUND CONDUCTOR SIZE20 AWG SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR32 SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
SURFACE TREATMENTNICKEL CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING260.0 CELSIUS